切换至 "中华医学电子期刊资源库"

中华神经创伤外科电子杂志 ›› 2016, Vol. 02 ›› Issue (03) : 152 -155. doi: 10.3877/cma.j.issn.2095-9141.2016.03.007

所属专题: 文献

临床研究

能谱CT低剂量扫描技术对急性脑外伤患者辐射防护的价值
宋飞鹏1,(), 石瑞1, 郜璐璐2, 王艺婷1, 林斌1, 李天平1, 曹义军1   
  1. 1. 030001 太原,山西医科大学第二医院放射科
    2. 450046 郑州,河南省骨科医院放射科
  • 收稿日期:2016-01-29 出版日期:2016-06-15
  • 通信作者: 宋飞鹏

Radiation protection of patients with acute cerebral trauma by low dose scanning technique of spectral CT: a primary study

Feipeng Song1,(), Rui Shi1, Lulu Gao2, Yiting Wang1, Bin Lin1, Tianping Li1, Yijun Cao1   

  1. 1. Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan 030001 China
    2. Department of Radiology, Orthopedics Hospital of Henan Province, Zhengzhou 450046, China
  • Received:2016-01-29 Published:2016-06-15
  • Corresponding author: Feipeng Song
  • About author:
    Corresponding author: Song Feipeng, Email:
引用本文:

宋飞鹏, 石瑞, 郜璐璐, 王艺婷, 林斌, 李天平, 曹义军. 能谱CT低剂量扫描技术对急性脑外伤患者辐射防护的价值[J]. 中华神经创伤外科电子杂志, 2016, 02(03): 152-155.

Feipeng Song, Rui Shi, Lulu Gao, Yiting Wang, Bin Lin, Tianping Li, Yijun Cao. Radiation protection of patients with acute cerebral trauma by low dose scanning technique of spectral CT: a primary study[J]. Chinese Journal of Neurotraumatic Surgery(Electronic Edition), 2016, 02(03): 152-155.

目的

研究能谱CT低剂量扫描技术对急性脑外伤患者头颅CT扫描的辐射防护的价值。

方法

选取自2015年10月至2015年12月因头颅外伤在山西医科大学第二医院放射科行头部CT扫描的患者31例,低剂量扫描方式获得图像为观察组,普通扫描方式获得图像为对照组,记录CT扫描生成的剂量参数,采用自身前后对照的方式,比较两组有效剂量E值、图像质量评分值的差异。

结果

观察组有效剂量E小于对照组(t=4.22,P<0.05),降低约50%,差异具有统计学意义。对照组和观察组的图像质量评分差异无统计学意义(t=0.38,P>0.05)。

结论

能谱CT低剂量扫描技术可以应用于急性头颅外伤患者的头部CT检查,不仅图像质量满足临床诊断,还可以有效降低患者因多次检查接受的辐射剂量。

Objective

To study the value of radiation protection by low dose scanning technique of spectral CT in patients with acute cerebral trauma.

Methods

31 cases who underwent CT scan of head due to cerebral trauma were selected from October 2015 to December 2015 in 2nd hospital of Shanxi medical university. The image by low dose scanning was obtained as the observation group, and in contrast the routine CT scan was the control group. Date of effective dose(ED) and the image quality score by CT scan were recorded and compared using self-control study.

Results

The ED of observation group was less than the control group which reduced 50%, and there was a significant difference between them(t=4.23, P<0.05). As for the image quality score, There was no significant difference between two groups(t=0.38, P>0.05).

Couclusion

Spectral CT low dose scanning technology can be applied to the patients, head scan when suffered acute brain trauma, not only the image quality meet the clinical diagnosis, but also can effectively reduce the radiation dose of patients with repeated examination.

图1 120 kVp的CT扫描影像
图2 80 kVp的CT扫描影像
表1 观察组与对照组有效剂量ED比较(mSv)
表2 观察组和对照组图像质量评分比较
[1]
王霄英.重视医学影像检查中的射线辐射防护[J].放射学实践, 2013, 28(3): 279-279.
[2]
Rapalino O,Kamalian S,Kamalian S, et al. Cranial CT with adaptive statistical iterative reconstruction: improve image quality with concomitant radiation dose reduction[J]. AJNR Am J Neuroradiol, 2012, 33(4): 609-615.
[3]
陶宗贵,陶然,贾守强,等.早期CT动态监测对急性脑外伤手术时机选择的指导价值[J].中国实用神经疾病杂志, 2014, (21): 36-37.
[4]
何洪波.早期CT动态监测在选择急性脑外伤手术时机中应用的意义分析[J].中国实用医药, 2013, 8(14): 78-79.
[5]
潘自强,周永增,周平坤,等.国际放射防护委员会第103号出版物,国际放射防护委员会2007年建议书[M].北京:原子能出版社, 2008: 50-51.
[6]
Advances in Radiation Protection in Medicine[C]. NCRP 43rd annual meeting, 2007: 240-241.
[7]
张翼,赵斌.低剂量螺旋CT扫描技术[J].医学影像学杂志, 2011, 21(9): 1438-1441.
[8]
Pearce MS,Salotti JA,Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumors: A retrospective cohort study[J]. Lancet, 2012, 380(9840): 499-505.
[9]
林晓珠,沈云,陈克敏,等. CT能谱成像的基本原理与临床应用研究进展[J].中华放射学杂志, 2011, 45(8): 798-800.
[10]
Leipsic J,Labounty TM,Heibron B, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study[J]. AJR Am J Roentgenol, 2010, 195(3): 665-660.
[11]
Leipsic J,Labounty TM,Heibron B, et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography[J]. AJR Am J Roentgenol, 2010, 195(3): 649-654.
[12]
范宝岩.能谱CT低剂量扫描技术在成人胸部扫描中的临床研究[D].吉林:吉林大学, 2012.
[13]
杨尚文,何健,杨献峰,等. ASiR算法结合自动管电流调制技术在胸部低剂量CT中的应用研究[J].医学影像学杂志, 2012, 22(1): 58-61.
[14]
关长旭,宋瑞娟,张浩亮,等.宝石能谱CT低剂量对比剂肺动脉成像[J].医学影像学杂志, 2015, (2): 226-229.
[15]
吕仁锋,于丽华,庄美俊,等.能谱CT双低剂量在头颈联合血管成像中的临床初探[J].中国临床医学影像杂志, 2014, 25(4): 275-277.
[16]
黄科峰,朱安平,陈洪高,等.宝石能谱CT电子束扫描技术低辐射剂量对冠状动脉成像的研究[J].临床军医杂志, 2011, 39(5): 977-978.
[17]
王艳,史大鹏,朱绍成,等.比较以自适应性统计迭代重建技术和滤过反投影重建的低剂量腹部CT的图像质量[J].中国医学影像技术, 2012, 28(10): 1902-1905.
[18]
Vorona GA,Zuccoli G,Sutcavage T, et al. The use of adaptive statistical iterative reconstruction in pediatric head CT: A feasibility study[J]. AJNR Am J Neuroradiol, 2013, 34(1): 205-211.
[1] 张伟, 王莉, 安彩霞, 王俭勤. 不同辐射防护措施对降低儿童先天性心脏病介入诊疗过程中辐射剂量的应用价值[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(04): 455-463.
[2] 王康, 陈冬梅, 刘基, 尹婷婷, 陈忠, 史清明. 多层螺旋CT及能谱CT在肺磨玻璃结节中的应用价值[J]. 中华肺部疾病杂志(电子版), 2022, 15(03): 361-363.
[3] 刘斌, 徐凯. 64排螺旋CT和宽体能谱CT在尘肺患者分期及二氧化硅沉积量评估中的作用[J]. 中华肺部疾病杂志(电子版), 2022, 15(03): 413-415.
[4] 马琼英, 余世勇, 余伟, 谷卓玉. 胸部智能毫安低剂量CT扫描的应用价值[J]. 中华肺部疾病杂志(电子版), 2017, 10(06): 728-729.
[5] 郭磊, 于莺, 郭卫星, 程树群. 能谱CT在原发性肝癌诊治中的应用[J]. 中华肝脏外科手术学电子杂志, 2019, 08(05): 384-387.
[6] 梅碧, 罗倩, 赵佳, 张蕾, 吴晓明. 双源CT能谱纯化单能量技术在评估喙锁韧带中的价值[J]. 中华肩肘外科电子杂志, 2022, 10(02): 135-140.
[7] 黄文鹏, 李莉明, 胡志伟, 刘晨晨, 邢静静, 高剑波. 能谱CT参数术前鉴别胃癌T3期和T4a期的价值[J]. 中华消化病与影像杂志(电子版), 2021, 11(06): 257-262.
[8] 彭云, 王猛, 罗先富, 朱庆强, 吴晶涛. 能谱CT对早期痛风降尿酸治疗疗效的定量评价[J]. 中华消化病与影像杂志(电子版), 2020, 10(02): 58-61.
[9] 苑呈秀, 盛华强, 王广丽, 张添钰. 能谱CT在非小细胞肺癌立体定向放疗预处理评估中的应用价值[J]. 中华诊断学电子杂志, 2019, 07(01): 7-10.
阅读次数
全文


摘要